The fittings you will actually use
Hardware stores stock hundreds of fittings, but a short list covers most repairs. Here is what each one does.
| Fitting | What it does | Typical use |
|---|---|---|
| Coupling | Joins two pipes of the same size in a straight line | Repairing a cut section. |
| Elbow (45 or 90 degree) | Changes direction | Turning a drain run. |
| Tee and wye | Creates a branch | Adding a sink or floor drain to a line. |
| Reducer or bushing | Joins two sizes | Stepping a pipe down. |
| Male or female adapter | Joins PVC to a threaded fitting | Connecting to a valve or a hose bib. |
| Cleanout plug | Gives access to clear a drain | A sewer cleanout. |
A wye turns flow gently, so drains use wyes where a tight tee would catch debris.
PVC types and where each belongs
Not all plastic pipe is the same. Mixing types is the most common mistake.
Schedule 40 PVC
The standard white pipe for drain, vent and cold pressure lines.
DWV PVC
Drain, waste and vent pipe, usually thinner, used only for non-pressure drains.
CPVC
A tan pipe rated for hot water, used in some supply lines. It is not the same as PVC.
PVC in sunlight
UV exposure makes PVC brittle, so exposed runs need paint or cover.
How to join PVC properly
PVC joints are chemical welds, so mistakes are permanent. Following the order gives a tight, lasting joint.
Cut square
Use a PVC cutter or a fine-tooth saw, and cut the pipe straight.
Deburr and dry fit
Remove burrs and test the fit before glue so you know the angle.
Prime and glue
Apply primer, then cement, to both surfaces. Work quickly.
Twist and hold
Push the pipe in with a quarter turn and hold for thirty seconds.
Cure before pressure
Wait the cure time on the can before running water through a joint.
PVC and building rules in Farmington
Farmington's building department lists plumbing systems among the work that needs a permit, and most permits also need a separate excavation permit through Public Works when digging is involved. A minor repair of an existing PVC drain may not need one, but a new run or a change to the drain layout often does. Ask the department about your project before you start.
Sprinkler systems add another rule. Kaysville's city page, for example, says drinking water is not allowed in outdoor sprinkler systems except in limited cases with documented permission, and backflow rules apply. Farmington homeowners with irrigation lines should confirm the local rule and the backflow device requirements with the city.
Source type: Farmington City building department pages and neighboring city codes.
Where PVC does not belong
Using the wrong pipe is a safety and code problem, not just a leak risk.
- Hot water supply lines, which need CPVC, PEX or copper.
- Anywhere the pipe is exposed to direct sunlight without protection.
- Gas lines.
- Pressurized lines that exceed the pipe's rating.
- Inside walls where code calls for a different material.
When to hand the job to a plumber
A single coupling to repair a cut sprinkler line is a safe homeowner job. A new drain branch, a change to venting or any work on the main drain needs correct slope, venting and often a permit. Our plumbing installation page covers fixtures and rough-in, and drain cleaning covers clogs that fittings cannot fix.
Older homes near the Main Street Historic District may have cast iron or galvanized pipe, which does not join to PVC with a simple coupling. A plumber can use transition couplings or replace a section so the joint is sound.
Sizing: what the numbers on pipe and fittings mean
PVC pipe is sold by nominal size, such as 1.5 inch or 2 inch, and the fitting must match that nominal size even though the real outside diameter is larger. Drain lines in houses are usually 1.5 inch for sinks, 2 inch for showers and washers, and 3 inch or 4 inch for toilets and main drains.
If you are not sure of the size, read the markings printed on the pipe. They show the nominal size, the schedule and the standard the pipe meets. Mixing sizes without a proper reducer creates leaks and clogs.
Safety and cleanup around PVC work
The glue and primer are solvents. A few simple habits make the job safe.
- Work in a ventilated area, since primer and cement give off strong fumes.
- Keep cement away from open flames and heat.
- Wear gloves and eye protection.
- Dispose of rags soaked in primer or cement properly.
- Keep children and pets away from cement and primer.
Repairing a cracked PVC drain
To repair a cracked section, cut out the damaged piece, slide a repair coupling over one end and join the pipe back together. A slip coupling lets you fit the new piece without moving the old pipe. After the glue cures, run water and watch the joint.
If the crack is in a main line under a slab or in a wall, call a plumber. See sewer line repair for what that work involves.
Common PVC mistakes and how to avoid them
The usual mistakes are cutting the pipe at an angle, skipping the primer, using too little cement, not holding the joint long enough and running water before the joint cures. Each produces a slow weep that appears days later. Another common mistake is using a tight 90 degree elbow in a horizontal drain, where a sweeping bend or two 45 degree fittings give better flow.
Keep a spare coupling or two in your toolbox. If a joint leaks after curing, cut it out and replace it instead of adding more glue on top.
A short PVC shopping list
Most repairs need only this short list from the hardware store.
- Pipe cutter or fine-tooth saw
- Deburring tool or sandpaper
- Primer and cement rated for the pipe type
- A few couplings, 45 degree elbows and a repair coupling
- Rags, gloves and eye protection
Not sure which fitting you need?
Call (385) 488-1892 to talk it through.
Questions from Farmington homeowners
No. Standard PVC softens with heat. Hot water lines use CPVC, PEX or copper.
CPVC is rated for higher temperatures and is usually tan or cream, while PVC is white. They use different cements.
Most plumbing codes call for primer on PVC drain and pressure joints. It cleans and softens the surface so the cement welds.
Farmington's building department lists plumbing systems among the work that needs a permit. A small repair may be exempt, so ask the department.
Yes. See our Centerville and Bountiful pages.
Follow the cure time on the cement can. Cold weather and larger pipe need longer.
Sources and where to verify
Written by the Farmington 24/7 Plumbing team using the public sources below, which you can check yourself.
- Farmington building department: Permit and excavation rules.
- Utah Division of Professional Licensing plumbing FAQ: Plumber licensing in Utah.
Plumbing work in Utah follows the International Plumbing Code (IPC) with Utah amendments, and plumbers working in Utah are expected to work to it.